Entreprises news

Maintenance of heating equipment

Source: Time:2021-07-19 09:48:28 views:

With the development of the times, the application of induction heating equipment is increasing, how healthy use induction heating equipment is also a focus of our concern. Today, GuangYuan · GuangZhiYuan Technology will introduce you to the induction heating equipment should pay attention. 6 points.
With the development of the times, the application of induction heating equipment is increasing, how healthy use induction heating equipment is also a focus of our concern. Today, GuangYuan · GuangZhiYuan Technology will introduce you to the induction heating equipment should pay attention. 6 points.
1. Periodically with compressed air or fan, the board is cleaned, and the film is blown, and it is best to once.
2. Clean a machine waterway every 3-6 months, when the machine is more water temperature alarm, it should be cleaned immediately when the water flow of water port is significantly reduced, and the detergent uses ordinary auto water tank detergent, press 1 / 40 proportion of dilution directly pump into the equipment waterway for cleaning.
3. Strictly implement the principle of power-on-in-water, it is strictly forbidden to water inadequate, and the internal and induction of cooling water and pressure can be required to meet the equipment. In order to avoid obstructing the cooling pipe, if water pump is supplied, the filter is mounted in the water pump water, the cooling water temperature cannot be higher than 47 ° C, and the water flow is 10t / h.
4. The inductor and multi-turns are kept clean, preventing the turret short circuit, the transformer contact surface and the sensor connecting plate should be clean without oxidity to ensure good conductivity. The inductor is replaced. After stopping heating, it can be carried out, the transformer contact surface and the inductor connecting plate are sanding with sandpaper to ensure good contact.
5. Anti-electricity, make sure that the cabinet is reliably grounded according to the electrician specification, first venting, detects water pressure and no water leakage. Then, the panel power switch can be turned on when the panel DC voltmeter is displayed in 500V.
6. The equipment should avoid sunshine, moist, dust, exposure and rain.